EML 45-M: Emission Labs 45 Mesh Plate Valve
The EML 45-M is Emission Labs’ mesh plate version of the Type 45, a directly heated output triode well suited to single-ended amplifiers driving high-efficiency loudspeakers. It retains the V-shaped filaments and standard four-pin base of the original 45. At the classic 275V operating point, one valve delivers around 2W into a 4.6kΩ output transformer primary. A matched pair serves both channels of a stereo single-ended amplifier.
The distinctive feature of the 45-M is its anode. A window of fine woven wire sits in a rigid metal frame, with the mesh extending across the inside edge of the frame. Friction where the wires cross helps damp mechanical ringing, while the frame carries heat away and keeps the anode spacing stable as the valve warms up.
Features
- Woven mesh window larger than the filament assembly, with a rigid surround to support the soft wire.
- Four V-shaped filaments retain the internal layout of the vintage Type 45. A gold-plated control grid helps keep grid current low and bias stable.
- Hand-blown glass bulb with a suspended anode and grid assembly, black ceramic UX4 base and gold-plated pins.
- Each valve carries an individual number on a metal tag inside the glass. Factory measurements are supplied on the box certificate.
For DIY builders, the current 45-M has a continuous anode dissipation rating of 13.5W. This allows a useful single-ended operating point of 300V at 39mA, giving around 2.5W into a 5–5.6kΩ primary. If you’re swapping valves, this operating point exceeds the 11W rating of the standard 45 and early 45 Mesh valves.
Manufacturer’s guarantee — The original purchaser can register the valves with Emission Labs within four weeks of receipt to take part in its five-year guarantee programme, subject to the Emission Labs guarantee conditions.
Specifications
- Valve type: Directly heated mesh plate output triode
- Base: Four-pin ceramic UX4
- Pin connections: Filament on pins 1 and 4, anode on pin 2, control grid on pin 3
- Filament supply per valve: 2.5V AC or DC at approximately 1.5A, with a voltage tolerance of ±5%
- Electronic filament supply: Voltage-regulated type
- Maximum standby time with filament supply only: 2 hours
- Maximum anode voltage: 300V
- Maximum anode current: 45mA
- Maximum continuous anode dissipation: 13.5W per valve for the current version, introduced in the third quarter of 2006
- Maximum Class A output: 3.5W per valve
- Typical single-ended output at 250V/34mA: 1.6W into a 3.9kΩ primary
- Typical single-ended output at 275V/36mA: 2W into a 4.6kΩ primary
- Typical single-ended output at 300V/39mA: 2.5W into a 5–5.6kΩ primary
- Amplification factor: 3.5
- Anode resistance at 275V/36mA: 1.67kΩ
- Transconductance at 275V/36mA: 2.1mA/V
- Maximum grid resistor: 500kΩ with cathode bias or 100kΩ with adjustable fixed bias
- Dimensions including base, excluding pins: 145mm high × 58mm diameter
- Weight per valve: 140g
Sold as a matched pair
PRICE (1 pair)
£620.00 +vat +p&p